CT-4008Q-5V100mA-124

4-Range Battery Testing System

This device is precise (0.01% F.S.*) with μA current output, suitable for testing Coin Cells, Super Capacitors, Three-Electrode Systems, and Battery Materials. It meets the needs of Material Manufacturers, Universities, and Research Institutes.


*32~104℉(0℃~40℃) (When the temperature is 77±50℉ (25±10℃), the accuracy error caused by temperature change is less than 50ppm /℃)


Product Parameters

CT-4008Q-5V100mA-124
Equipment name 4-Range Battery Testing System
Index items Index parameters
Voltage Constant Voltage Range Control 10mV~5V
Voltage Minimum Discharge Voltage -5V
Voltage Accuracy ±0.02% F.S.
Voltage Stability ±0.02% F.S.
Current Output Range per Channel 0.2μA ~ 0.1mA;0.1mA ~ 1mA;1mA ~ 10mA;10mA ~ 100mA
Current Accuracy ± 0.02% F.S.
Current Constant Voltage Cut-off Current 0.1μA;1μA;1μA;0.1mA;
Current Stability ± 0.02% F.S.
Power Single Channel Maximum Output Power 0.5W;
Power Stability ± 0.2% F.S.
Input Active Power 25W
Resolution AD 24bit
Resolution DA 16bit
Input Impedance ≥1GΩ
Size of Each Unit (W*D*H)(mm) 1U(19"),483.6*321.5*48.5 (mm)

Features

Keep improving and lead the market.

4-Range
4-Range
Accuracy 0.01% F.S.
Accuracy 0.01% F.S.
Rise Time ≤ 500μs
Rise Time ≤ 500μs
Recording Frequency 100Hz
Recording Frequency 100Hz
Min. Pulse Width <500ms
Min. Pulse Width <500ms
Current Output
Current Output
dQ/dV Curve
dQ/dV Curve
DCIR Test
DCIR Test
HPPC
HPPC

1U small size

We can see equipment's unit ID via LCD. What's more, 164 air socket is used to connect clamps and coin cells. CT-4000-mA equipment has already became the classic equipment, which is widely used in universities, laboratories and research institutes, and much much more.



1U small size

External simplicity. Internal precision.

Hanger: Fixing equipment on testing rack.

Switch: Start button.

Digital display: Display equipment number from 1 to 32.

External simplicity. Internal precision.

High efficiency cooling system

NEWARE new cooling system is much safer and higher efficiency than before. Air inlet occupies the half of the left and right sides. 


High efficiency cooling system

Plug the cable into the network interface & switch on the power

We can see the RS-485 interface and AC power supply on the back, which connect the control unit and equipment via Ethernet cable.

Plug the cable into the network interface & switch on the power

dQ/dV

dQ/dV differential capacity curve: the peak on the curve indicates that there is a voltage plateau on the charge and discharge curve, and different peaks represent different electrochemical reactions. 

Conditions switches

Battery test steps need to be estimated for multiple conditions according to different operations during test applications; condition switches meet requirements for multi-exit programming types. "And""or" logic operation, "≥", "≤", "=" comparison; time duration "t", can meet control requirements for special tests. Each step supports 5 condition switches; support multi-exits, go to any steps, achieve more flexible process control.

Segment-record conditions

Supports recording settings for voltage, current and time; 

3 segment recording conditions can be set for each step; 

each segment can be set: ∆T, ∆V and ∆I.

Control peripheral equipment by communication

The BTS server makes it possible to control the communication of the peripheral equipment (battery tester & automation) via the switch.

Super-capacitor Testing

The unit of Q is Coulomb, 1 Coulomb = 1A * 1s = 1As; 1Ah = 3600 As(Amp Second); Work voltage U = Charge upper limited voltage - Discharge bottom limited voltage; working voltage can be set and the EDLC coulomb could be calculated automatically by the software.

DBC configuration function

Support DBC files import/ edit/ export. Different battery pack protocols just needs modifying DBC protocol file's code without upgrade the program, so that it can realize communication. The system is flexible and practical.

Constant Current / Voltage Charge / Discharge Test

The constant current and constant voltage are integrated into a work step. After the constant current charged / discharged to the specified voltage, it is seamlessly switched to the constant voltage mode to supply the power of the battery pack. The switching process is smooth without spikes.

Download Manual

Click the download button on the right to download the product specification
Auxilaries and Optional Accessories
Popular Battery Test Equipment