FAQ is designed to assist users in swiftly resolving issues encountered during software installation, device usage, and testing processes. They ensure adherence to correct procedures, thus providing the most accurate measurement results possible.
Clean up disk space or replace the SD card.
Previous
Next
Facing the issue of full disk space on your server and need to relocate your database to a new disk? Follow this step-by-step procedure to ensure a seamless transition:
Check if the negative power supply is working properly. Devices without a negative power supply will have lower current as the voltage decreases (devices with 6A or above have a negative power supply). Verify if the displayed and set voltage and current values are consistent.
Check the computer's running memory, end processes occupying memory, and ensure that the memory usage rate does not exceed 90%. After disabling the firewall and antivirus software, restart the software. If the issue persists, then reinstall the software. Before reinstalling, please uninstall or disable the firewall and antivirus software.
Solution 1: Check if the network cable and port are well connected. Solution 2: Restart the host computer, change the boot sequence (start the lower computer before the host computer), and then remap. Remapping correction plan: If the mapping is incorrect while the channel is in the running state and cannot be reset, first pause the channel, save the data, then right-click and select "Clear Flag," enter "Mapping Settings," right-click and select "Undo Current Channel," then remap the channel and save the mapping. Solution 3: Modify the equipment box number through calibration software/box number modification software (please contact after-sales support to resolve the issue).
Regarding the accessory issue, we suggest purchasing the required components and then, under the guidance of the after-sales department, you can replace them yourself. Please note that the specific steps for replacement may vary depending on the different devices.
Solution 1. Check if the fixture has poor contact. Solution 2. If the equipment tests battery capacity decay rapidly, check the equipment accuracy and test chamber performance. Solution 3. Upgrade the control unit program. Upgrading the control unit may have risks, please contact the after-sales department for assistance.
December 06,2022
The 48th Solid State Ion Symposium will be held in Sendai, Japan, from December 6 to December 8, 2022.
June 23,2024
Welcome to The International Symposium on Polymer Electrolytes (ISPE-18)The International Symposium on Polymer Electrolytes (ISPE-18) Conference is organized by the American Chemical Society (ACS) Mal
June 28,2023
Batteries UK Birmingham is an international exhibition for the electric vehicle industry, dedicated to improving battery performance, cost and safety for manufacturers, users and the entire supply cha
March 01,2019
NEWARE was attended the BATTERY JAPAN 2019-Int’l Rechargeable Battery Expo from Feb. 27 at Tokyo Big Sight, Japan.
March 15,2023
The 14th Tokyo International Secondary Battery Exhibition takes place from March 15th - March 17th, in Japan.BATTERYJAPAN is the world's largest exhibition and conference for the manufacture and devel
September 26,2022
The 2022 MRS Fall Meeting will be held November 27 – December 2, 2022, in Boston, Massachusetts, at the Hynes Convention Center and adjacent Sheraton Boston Hotel, and then December 6 – 8 in a virtual format.